Editar ítem
Campo
Valor
Lang
Editar
dc.contributor.advisor
Valor
Lang
Editar
Molina-Díaz, Antonio
Ruiz-Medina, Antonio
dc.contributor.author
Valor
Lang
Editar
Ruedas-Rama, María-José
dc.contributor.other
Valor
Lang
Editar
Universidad de Jaén. Departamento de Química Física y Analítica
es_ES
dc.date.accessioned
Valor
Lang
Editar
2012-12-20T12:32:09Z
dc.date.available
Valor
Lang
Editar
2012-12-20T12:32:09Z
dc.date.issued
Valor
Lang
Editar
2006
dc.description.abstract
Valor
Lang
Editar
[EN] In this Memory it is showed the development of ten spectroscopic continuous flow sensors for the automatic determination of organic and inorganic species of environmental and pharmaceutical interest. These sensors have been classified according to the developed methodology in sensors with or without renovation of the sensing surface.
Three flow sensors without renovation of the sensing surface ha ve been developed using this methodology, one of them uses spectrophotometric detection and two of them spectrofluorimetric detection, based on the measurement of the absorbance in UV region or the intrinsic fluorescence of the analytes. In all these cases it is not
necessary previous derivation reactions.
The seven developed sensors with renovation of the sensing surface are based on the concept of Bead Injection Spectroscopy. The use of this methodology is justified when the species of interest is strongly retained on the sensing surface and the regeneration of the support is not possible in suitable conditions or becomes extraordinarily difficult. The methodology used in these seven sensors is based on the injection of an exact volume of a homogenous beads suspension in a flow injection analysis system with spectroscopic detection. The beads (solid support) are loaded in the flow cell placed in the detection zone of a nondestructive spectroscopic detector. At the end of the analysis, the beads are discarded by reversing the flow and instantaneously transported out of the system, being replaced the sensing surface after each measurement.
In all cases, a great study of the experimental variables that can affect this type of sensors has been performed. Next, the sensors were calibrated for the corresponding analytes, finding a calibration equation that allowed relating the values of the analytical signals with the concentration of the sample. The method used in all the cases was the univariante ca libration. Studies of interferences were made to know the response of the sensor in presence of the organic and inorganic compounds that usually accompany the analytes in the rea l samples. In the case of serious interferences occurring, appropriate modifications for their elimination were designed. Finally, the proposed sensors were applied to the determination of these analytes in samples of different nature. The results confirm the validity of the proposed sensors.
es_ES
dc.description.provenance
Valor
Lang
Editar
Submitted by Baltar Gómez Ana (aibaltar@ujaen.es) on 2012-12-20T12:32:09Z
No. of bitstreams: 2
8484393054.pdf: 3308444 bytes, checksum: 74710cde331518cb27fb497ea390ad72 (MD5)
license_rdf: 23599 bytes, checksum: 9e2b7f6edbd693264102b96ece20428a (MD5)
en
Made available in DSpace on 2012-12-20T12:32:09Z (GMT). No. of bitstreams: 2
8484393054.pdf: 3308444 bytes, checksum: 74710cde331518cb27fb497ea390ad72 (MD5)
license_rdf: 23599 bytes, checksum: 9e2b7f6edbd693264102b96ece20428a (MD5)
Previous issue date: 2006
en
dc.description.sponsorship
Valor
Lang
Editar
Tesis Univ. Jaén. Departamento de Química Física y Analítica. Leída el 21 de enero de 2005
es_ES
dc.identifier.isbn
Valor
Lang
Editar
8484393054
dc.identifier.uri
Valor
Lang
Editar
http://hdl.handle.net/10953/432
dc.language.iso
Valor
Lang
Editar
spa
es_ES
dc.publisher
Valor
Lang
Editar
Jaén : Universidad de Jaén
es_ES
dc.rights
Valor
Lang
Editar
Licencia Reconocimiento-NoComercial-SinObraDerivada 3.0 España
es_ES
dc.rights.accessRights
Valor
Lang
Editar
info:eu-repo/semantics/openAccess
es_ES
dc.rights.uri
Valor
Lang
Editar
http://creativecommons.org/licenses/by-nc-nd/3.0/es/
es_ES
dc.subject
Valor
Lang
Editar
Análisis espectral
es_ES
Química analítica
es_ES
dc.subject.udc
Valor
Lang
Editar
543
es_ES
dc.title
Valor
Lang
Editar
Optosensores en flujo : de la regeneración a la renovación de la superficie sensora
es_ES
dc.type
Valor
Lang
Editar
info:eu-repo/semantics/doctoralThesis
es_ES
europeana.dataProvider
Valor
Lang
Editar
Universidad de Jaén. España
es_ES
europeana.rights
Valor
Lang
Editar
http://creativecommons.org/licenses/by-nc-nd/3.0/es/
es_ES
europeana.type.TEXT
Valor
Lang
Editar
TEXT
es_ES